Bridge (ID- 770 ) Inventory Report

Hinduwala Bridge On Chainage 24.250 of Shahid Gajender Singh Bisht Road) state highway (Majra Bhuddi Shekhuwala Dharmawala road)

Data finalized On 20 Feb 2024

By Er. Maan Singh

Last Rated On 14 May 2024

Rating 0.00%

Categorized As

XXXXX on XX-XX-XXXX

In District : Dehradun Under Division : CD Dehradun

General

Bridge Type : Motor Bridge High Level
Structure No : 24/1
Feature Intersected : Local River
Name of Bridge : Hinduwala Bridge
Nearest Town : Hinduwala
Latitude (Northing) : 30.36092400
Longitude (Easting) : 77.80448500
Construction Year : 2011
Inventory Year : 2021

Geometric

Overall length (in meter) : 33.60
Total No of Span : 6
Maximuam Span (in meter) : 33.60
Span Arragment : 4x5+2x6.8
No of Lane : 2.000
Overall Width (m) : 7.500
Carriageway Width (m) : 7.500
RS Footpath Width (m) : 0.000
LS Footpath Width (m) : 0.000
Approch Width i/c Shoulders (m) : 10.000
Gradient (%age) : 3
Skew Angle (degree) : 0.00
Radius of Curve in Plan (if Any) : 0.00

Design Data

HFL Highest Flood Level :
OFL Ordinary Flood Level :
LWL Low Water Level :
Design Velocity (m/Sec) :
Design Discharge (Cumecs) :
Soffit Level at Centre :
Road Level at Centre :
Design Scour Level at Pier :
Design Scour Level at Abutments :
Exposure Condition : Moderate
Seismic Importance factor : 1.0
Design Loading : Class A
Load Rating : Class A

Super-Structure

Superstructure Type : Single/Multi-cell Box
Superstructure Material : Reinforced concrete
Wearing Coat Type : Bituminous Concrete
Expension Joint Type : Other
Railing/Crash Barrier type : Cast-in-situ concrete
Bearing type : other

Sub-Structure

Founding Strata : Bouldery
Abutment Foundation Type : Raft
Pier Foundation Type : Raft
No of Piers : 5
Abutment Type : RCC Box type
Pier Type : RCC Solid

Protection Work

Bank Protection Left Side of Up-stream : no protection work provided
Bank Protection Right Side of Up-stream : RR Stone masonery
Bank Protection Left Side of Down-stream : no protection work provided
Bank Protection Right Side of Down-stream : RR Stone masonery
Floor Protection on Up-stream : no protection work provided
Floor Protection on Down-stream : no protection work provided