Bridge (ID- 776 ) Inventory Report

Local Nala setu

Data finalized On 27 Sep 2021

By Er. Suresh Singh Martoliya

Last Rated On 21 Jun 2024

Rating 0.00%

Categorized As

XXXXX on XX-XX-XXXX

In District : Nanital Under Division : CD Haldwani

General

Bridge Type : Motor Bridge High Level
Structure No : 10.65x1
Feature Intersected : Local Nala
Name of Bridge : Local Nala setu
Nearest Town : I.TI. Dhanmil Chauraha
Latitude (Northing) : 29.20666667
Longitude (Easting) : 79.51527778
Construction Year : 1996
Inventory Year : 2021

Geometric

Overall length (in meter) : 10.65
Total No of Span : 1
Maximuam Span (in meter) : 10.65
Span Arragment : 1x10.65
No of Lane : 2.000
Overall Width (m) : 11.700
Carriageway Width (m) : 9.300
RS Footpath Width (m) : 0.000
LS Footpath Width (m) : 0.000
Approch Width i/c Shoulders (m) : 11.700
Gradient (%age) : 0
Skew Angle (degree) : 0.00
Radius of Curve in Plan (if Any) : 0.00

Design Data

HFL Highest Flood Level :
OFL Ordinary Flood Level :
LWL Low Water Level :
Design Velocity (m/Sec) :
Design Discharge (Cumecs) :
Soffit Level at Centre :
Road Level at Centre :
Design Scour Level at Pier :
Design Scour Level at Abutments :
Exposure Condition : Mild
Seismic Importance factor : 1.0
Design Loading : Class B
Load Rating : Class B

Super-Structure

Superstructure Type : Solid slab
Superstructure Material : Reinforced concrete
Wearing Coat Type : Bituminous Concrete
Expension Joint Type : Not Provided
Railing/Crash Barrier type : other
Bearing type : Not Provided

Sub-Structure

Founding Strata : Sandy
Abutment Foundation Type : Open
Pier Foundation Type : NA
No of Piers : 0
Abutment Type : Stone Masonry
Pier Type : RCC Solid

Protection Work

Bank Protection Left Side of Up-stream : R.R. 1:6 Stone masonry
Bank Protection Right Side of Up-stream : R.R. 1:6 Stone masonry
Bank Protection Left Side of Down-stream : R.R. 1:6 Stone masonry
Bank Protection Right Side of Down-stream : R.R. 1:6 Stone masonry
Floor Protection on Up-stream : no protection work provided
Floor Protection on Down-stream : no protection work provided
Tratment for Corrosion Protection (if any) : no special treatment provided