Bridge (ID- 836 ) Inventory Report

near Himani Gas Godown road On Chainage 1.704 of Rajpur Saheed Esthal Rajesh Rawat Colony Raipur to Himani Gas Godown road

Data Yet Not Finalized

Last Rated On 13 Jun 2024

Rating 2.22%

Categorized As

XXXXX on XX-XX-XXXX

In District : Tehri Under Division : PD Dehradun

General

Bridge Type : Motor Bridge High Level
Structure No : 02/01
Feature Intersected : Rispana River
Name of Bridge : near Himani Gas Godown road
Nearest Town : new basti , R.K.Puram
Latitude (Northing) : 30.36499900
Longitude (Easting) : 78.72233300
Construction Year :
Inventory Year : 2021

Geometric

Overall length (in meter) : 21.00
Total No of Span : 2
Maximuam Span (in meter) : 10.50
Span Arragment : 2x10.50
No of Lane : 2.000
Overall Width (m) : 8.350
Carriageway Width (m) : 7.450
RS Footpath Width (m) : 0.000
LS Footpath Width (m) : 0.000
Approch Width i/c Shoulders (m) : 9.350
Gradient (%age) : 0
Skew Angle (degree) : 0.00
Radius of Curve in Plan (if Any) : 0.00

Design Data

HFL Highest Flood Level :
OFL Ordinary Flood Level :
LWL Low Water Level :
Design Velocity (m/Sec) :
Design Discharge (Cumecs) :
Soffit Level at Centre :
Road Level at Centre :
Design Scour Level at Pier :
Design Scour Level at Abutments :
Exposure Condition : Moderate
Seismic Importance factor : 1.0
Design Loading : Class B
Load Rating : Class B

Super-Structure

Superstructure Type : Single/Multi-cell Box
Superstructure Material : Reinforced concrete
Wearing Coat Type : Cement Concrete
Expension Joint Type : Single Strip/Box Seal Joint
Railing/Crash Barrier type : Tubular steel
Bearing type : Not Provided

Sub-Structure

Founding Strata : Bouldery
Abutment Foundation Type : Raft
Pier Foundation Type : NA
No of Piers : 0
Abutment Type : RCC Box type
Pier Type : NA

Protection Work

Bank Protection Left Side of Up-stream : no protection work provided
Bank Protection Right Side of Up-stream : no protection work provided
Bank Protection Left Side of Down-stream : no protection work provided
Bank Protection Right Side of Down-stream : no protection work provided
Floor Protection on Up-stream : no protection work provided
Floor Protection on Down-stream : no protection work provided
Tratment for Corrosion Protection (if any) : no special treatment provided