Bridge (ID- 912 ) Inventory Report

Kunigarh Local Gadhera On Chainage 1.136 of Tarikhet Pipli Manjurkhan motor road

Data finalized On 25 Jul 2022

By Sukeerti Rathore

Last Rated On 07 Aug 2024

Rating 2.38%

Categorized As

XXXXX on XX-XX-XXXX

In District : Almora Under Division : PD Ranikhet

General

Bridge Type : Motor Bridge High Level
Structure No : 2/1
Feature Intersected : Kunigarh Local Gadhera
Name of Bridge : Kunigarh Local Gadhera
Nearest Town : Tarikhet
Latitude (Northing) : 29.61706900
Longitude (Easting) : 79.39884700
Construction Year : 2003
Inventory Year : 2021

Geometric

Overall length (in meter) : 6.00
Total No of Span : 1
Maximuam Span (in meter) : 6.00
Span Arragment : 1x6
No of Lane : 1.000
Overall Width (m) : 7.000
Carriageway Width (m) : 7.000
RS Footpath Width (m) : 0.000
LS Footpath Width (m) : 0.000
Approch Width i/c Shoulders (m) : 8.500
Gradient (%age) : 0
Skew Angle (degree) : 0.00
Radius of Curve in Plan (if Any) : 0.00

Design Data

HFL Highest Flood Level :
OFL Ordinary Flood Level :
LWL Low Water Level :
Design Velocity (m/Sec) :
Design Discharge (Cumecs) :
Soffit Level at Centre :
Road Level at Centre :
Design Scour Level at Pier :
Design Scour Level at Abutments :
Exposure Condition : Moderate
Seismic Importance factor : 1.0
Design Loading : Class B
Load Rating : Class B

Super-Structure

Superstructure Type : Solid slab
Superstructure Material : Reinforced concrete
Wearing Coat Type : Cement Concrete
Expension Joint Type : Not Provided
Railing/Crash Barrier type : Tubular steel
Bearing type : Not Provided

Sub-Structure

Founding Strata : Bouldery
Abutment Foundation Type : Open
Pier Foundation Type : NA
No of Piers : 0
Abutment Type : Stone Masonry
Pier Type : NA

Protection Work

Bank Protection Left Side of Up-stream : 1:6 Cement masonry wall length 12m
Bank Protection Right Side of Up-stream : 1:6 Cement masonry wall length 8m
Bank Protection Left Side of Down-stream : no protection work provided
Bank Protection Right Side of Down-stream : no protection work provided
Floor Protection on Up-stream : CC Floor 2m Length
Floor Protection on Down-stream : CC Floor 5m Length
Tratment for Corrosion Protection (if any) : no special treatment provided