ID :1583
स्वतंत्रता संग्राम सैनानी ”वृक्ष मानव“ श्री विश्वेश्वर दत्त सकलानी मोटर मार्ग कि0मी0-9 है0मी0 0-2
on Chainage 8.050 of Freedom fighter Shri Vishveshwar Dutt Saklani motor road (Raipur Kaddukhal state highway)
In District Tehri Under TD Thathyd Division
Critical Report on Bridge Condition
Form Filled By Surendra Kumar [90007790]
Inspection Team
Detail Report
| # | Parameter | Problem ? | How Bad? | How Much? | |
|---|---|---|---|---|---|
| 1 | ROAD APPROCHES AND DECK Component Weightage 10 | ||||
| A- ROAD SURFACE NEAR BRIDGE | |||||
| a) Bumpy road surface near bridge? | Yes | Not So Bad | Some Qty | 2 | |
| B- DRAINAGE | |||||
| a) Badly built road drainage near bridge? | Yes | Not So Bad | Some Qty | 2 | |
| b) Blocked or damaged road drains? | Yes | Not So Bad | Much Qty | 3 | |
| c) Water on the deck? | NO Problem | -- | -- | 0 | |
| d) Blocked or damaged deck drains? | Yes | Not So Bad | Some Qty | 2 | |
| C- WEARING COAT | |||||
| CONCRETE WEARING COURSE | |||||
| a) Cracking? | Yes | Bad | Some Qty | 5 | |
| b) Spalling? | NO Problem | -- | -- | 0 | |
| c) Reinforcement exposed? | Yes | Bad | Much Qty | 6 | |
| d) Poor concrete? | Yes | Bad | Some Qty | 5 | |
| e) Wear of surface due to small stones? | NO Problem | -- | -- | 0 | |
| D- KERBS & FOOTPATHS | |||||
| a) Loose railing fixtures? | NO Problem | -- | -- | 0 | |
| a) Damaged or loose kerbs? | Yes | Not So Bad | Not Much Qty | 1 | |
| 2 | PARAPETS, RAILINGS AND CRASH BARRIERS Component Weightage 10 | ||||
| a) Impact damaged? | Yes | Very Bad | Much Qty | 9 | |
| b) Loose or damaged fixings? | Yes | Very Bad | Some Qty | 8 | |
| c) Loose base of posts? | NO Problem | -- | -- | 0 | |
| d) Damaged coatirig or paint on steel surface? | Yes | Very Bad | Not Much Qty | 7 | |
| e) Corrosion on steel surface? | Yes | Bad | Not Much Qty | 4 | |
| f) Cracking on Masonary Parapets? | NO Problem | -- | -- | 0 | |
| g) Movement or bending of parapet? | Yes | Very Bad | Much Qty | 9 | |
| h) Poor pointing/ Plaster on parapet? | NO Problem | -- | -- | 0 | |
| i) Deterioration of bricks or stones? | Yes | Very Bad | Some Qty | 8 | |
| 3 | EXPANSION JOINT AT ABUTMENTS & PIERS Component Weightage 10 | ||||
| a) Damage to concrete of deck end or dirt wall near joint? | Yes | Very Bad | Much Qty | 9 | |
| b) Debris or vegetation in joint? | Yes | Bad | Not Much Qty | 4 | |
| c) Loose or damaged fixtures? | Yes | Bad | Much Qty | 6 | |
| d) Damage or corrosion to metal parts? | Yes | Bad | Some Qty | 5 | |
| e) Damage to rubber waterseals? | Yes | Very Bad | Some Qty | 8 | |
| 4 | RIVER Component Weightage 10 | ||||
| A- BLOCKAGES IN WATERWAY | |||||
| a) Debris against piers or abutments? | NO Problem | -- | -- | 0 | |
| b) Remains of old bridge under or upstream of the bridge? | NO Problem | -- | -- | 0 | |
| c) Fencing or buildings under bridge? | NO Problem | -- | -- | 0 | |
| d) Trees or bushes.growing under bridge? | NO Problem | -- | -- | 0 | |
| B- CHANGE IN RIVER COURSE | |||||
| a) River changing path upstream of bridge? | Yes | Bad | Much Qty | 6 | |
| b) New islands forming upstream of bridge? | Yes | Bad | Some Qty | 5 | |
| C- RIVER TRAINING WORKS | |||||
| a) River attack beyond the upstream end of river training works? | Yes | Very Bad | Much Qty | 9 | |
| b) Damage to walls? | Yes | Very Bad | Much Qty | 9 | |
| c) Loss of pitching? | Yes | Very Bad | Some Qty | 8 | |
| d) Damage to crates, timber, fencing, etc.? | NO Problem | -- | -- | 0 | |
| e) Damage to trees? | NO Problem | -- | -- | 0 | |
| 5 | SUPERSTRUCTURE Component Weightage 60 | ||||
| STEEL TRUSSES | |||||
| General | |||||
| a) Impact damage to girders, trusses or bracings? | Yes | Not So Bad | Not Much Qty | 1 | |
| b) Debris or vegetation on beams, girders, trusses bracings or joints? | Yes | Not So Bad | Not Much Qty | 1 | |
| c) Water coming through the deck? | Yes | Very Bad | Not Much Qty | 7 | |
| d) Water from the deck drainage flowing on to girders, trusses, beams or bracings? | NO Problem | -- | -- | 0 | |
| e) Not enough vertical & horizontal clearances? | Yes | Not So Bad | Some Qty | 2 | |
| STEEL TRUSSES | |||||
| a) Deterioration of paint or galvanising? | Yes | Very Bad | Not Much Qty | 7 | |
| b) Corrosion? | Yes | Very Bad | Not Much Qty | 7 | |
| c) Bends in members? | Yes | Not So Bad | Not Much Qty | 1 | |
| d) Bent or damaged joints? | NO Problem | -- | -- | 0 | |
| e) Bent or damaged bracing? | Yes | Not So Bad | Not Much Qty | 1 | |
| f) Loose bolts or rivets? | NO Problem | -- | -- | 0 | |
| g) Cracking of steel members? | Yes | Not So Bad | Not Much Qty | 1 | |
| STEEL UNDERSIDE OF DECK | |||||
| a) Deterioration of paint or galvanising? | NO Problem | -- | -- | 0 | |
| b) Corrosion? | Yes | Not So Bad | Not Much Qty | 1 | |
| c) Bends in stringers or plates? | Yes | Not So Bad | Not Much Qty | 1 | |
| d) Loose bolts or rivets? | Yes | Not So Bad | Not Much Qty | 1 | |
| e) Cracking? | NO Problem | -- | -- | 0 | |
| 6 | BEARINGS Component Weightage 10 | ||||
| METAL BEARINGS | |||||
| a) Debris or vegetation around bearings? | Yes | Not So Bad | Not Much Qty | 1 | |
| b) Bad drainage? | Yes | Not So Bad | Much Qty | 3 | |
| c) Not enough room for the bridge span to move? | NO Problem | -- | -- | 0 | |
| d) Bearing not seated properly? | NO Problem | -- | -- | 0 | |
| e) Bridge span not seated properly on bearing? | NO Problem | -- | -- | 0 | |
| f) Damaged bedding mortar? | NO Problem | -- | -- | 0 | |
| g) Damaged or loose earthquake restraints? | NO Problem | -- | -- | 0 | |
| METAL BEARINGS | |||||
| a) Parts not properly seated? | NO Problem | -- | -- | 0 | |
| b) Parts not free to move? | NO Problem | -- | -- | 0 | |
| c) Problem with the lubrication system? | NO Problem | -- | -- | 0 | |
| d) Sliding surfaces damaged? | NO Problem | -- | -- | 0 | |
| e) Cracks or bends in metal parts/ Bearing? | NO Problem | -- | -- | 0 | |
| f) Corrosion of metal parts? | Yes | Not So Bad | Some Qty | 2 | |
| 7 | Right Side ABUTMENT, WING WALLS & RETAINING WALLS Component Weightage 10 | ||||
| A- GENERAL | |||||
| a) Erosion or scour at abutment? | Yes | Very Bad | Some Qty | 8 | |
| b) Damage to foundation? | Yes | Bad | Not Much Qty | 4 | |
| c) Movement of abutment? | NO Problem | -- | -- | 0 | |
| d) Debris against abutment? | Yes | Not So Bad | Some Qty | 2 | |
| e) Vegetation growing on-or in abutment? | NO Problem | -- | -- | 0 | |
| f) Scour near to retaining walls? | Yes | Very Bad | Much Qty | 9 | |
| g) Movement of retaining walls? | NO Problem | -- | -- | 0 | |
| h) Water leaking down through the expansion joint? | Yes | Bad | Not Much Qty | 4 | |
| B- DRAINAGE SYSTEM | |||||
| a) Not enough weepholes? | NO Problem | -- | -- | 0 | |
| b) Weepholes not working? | NO Problem | -- | -- | 0 | |
| c) Water leaking through the abutment? | Yes | Not So Bad | Some Qty | 2 | |
| C- CONCRETE WALLS | |||||
| a) Cracking? | NO Problem | -- | -- | 0 | |
| b) Spalling? | NO Problem | -- | -- | 0 | |
| c) Corrosion of reinforcement? | NO Problem | -- | -- | 0 | |
| d) Poor concrete? | NO Problem | -- | -- | 0 | |
| D- MASONRY WALLS | |||||
| a) Cracking? | Yes | Not So Bad | Some Qty | 2 | |
| b) Bulging? | NO Problem | -- | -- | 0 | |
| c) Poor pointing? | Yes | Not So Bad | Some Qty | 2 | |
| d) Deterioration of bricks or stones? | NO Problem | -- | -- | 0 | |
| E- EMBANKMENTS AND FILL IN FRONT OF ABUTMENT | |||||
| a) Scour at base of slopes? | Yes | Not So Bad | Much Qty | 3 | |
| b) Slippage of fill? | NO Problem | -- | -- | 0 | |
| c) Erosion of fill? | Yes | Not So Bad | Some Qty | 2 | |
| d) Cracking of road or embankment edge? | NO Problem | -- | -- | 0 | |
| e) Piping failure of fill? | NO Problem | -- | -- | 0 | |
| 8 | Left Side ABUTMENT, WING WALLS & RETAINING WALLS Component Weightage 10 | ||||
| A- GENERAL | |||||
| a) Erosion or scour at abutment? | Yes | Not So Bad | Some Qty | 2 | |
| b) Damage to foundation? | Yes | Not So Bad | Some Qty | 2 | |
| c) Movement of abutment? | Yes | Not So Bad | Not Much Qty | 1 | |
| d) Debris against abutment? | NO Problem | -- | -- | 0 | |
| e) Vegetation growing on-or in abutment? | Yes | Not So Bad | Not Much Qty | 1 | |
| f) Scour near to retaining walls? | NO Problem | -- | -- | 0 | |
| g) Movement of retaining walls? | Yes | Not So Bad | Not Much Qty | 1 | |
| h) Water leaking down through the expansion joint? | NO Problem | -- | -- | 0 | |
| B- DRAINAGE SYSTEM | |||||
| a) Not enough weepholes? | Yes | Not So Bad | Some Qty | 2 | |
| b) Weepholes not working? | NO Problem | -- | -- | 0 | |
| c) Water leaking through the abutment? | Yes | Not So Bad | Some Qty | 2 | |
| C- CONCRETE WALLS | |||||
| a) Cracking? | NO Problem | -- | -- | 0 | |
| b) Spalling? | NO Problem | -- | -- | 0 | |
| c) Corrosion of reinforcement? | NO Problem | -- | -- | 0 | |
| d) Poor concrete? | NO Problem | -- | -- | 0 | |
| D- MASONRY WALLS | |||||
| a) Cracking? | NO Problem | -- | -- | 0 | |
| b) Bulging? | NO Problem | -- | -- | 0 | |
| c) Poor pointing? | NO Problem | -- | -- | 0 | |
| d) Deterioration of bricks or stones? | NO Problem | -- | -- | 0 | |
| E- EMBANKMENTS AND FILL IN FRONT OF ABUTMENT | |||||
| a) Scour at base of slopes? | NO Problem | -- | -- | 0 | |
| b) Slippage of fill? | NO Problem | -- | -- | 0 | |
| c) Erosion of fill? | NO Problem | -- | -- | 0 | |
| d) Cracking of road or embankment edge? | NO Problem | -- | -- | 0 | |
| e) Piping failure of fill? | NO Problem | -- | -- | 0 | |
| 9 | Embankments Component Weightage 10 | ||||
| A- STONE PITCHING SLOPE PROTECTION | |||||
| a) Cracking? | NO Problem | -- | -- | 0 | |
| b) Poor pointing? | NO Problem | -- | -- | 0 | |
| c) Scour or erosion at edge? | Yes | Bad | Some Qty | 5 | |
| d) Pieces broken off? | NO Problem | -- | -- | 0 | |
| e) Piping failure of fill? | NO Problem | -- | -- | 0 | |
| B- SLOPE PROTECTION WITH CRATES | |||||
| a) Not much movement of crates? | Yes | Very Bad | Some Qty | 8 | |
| b) Damage to crates or ties? | NO Problem | -- | -- | 0 | |
| C- PITCHING SLOPE PROTECTION WITH CONCRETE BLOCKS | |||||
| a) Slope getting washed out? | Yes | Very Bad | Much Qty | 9 | |
| b) Settlement? | NO Problem | -- | -- | 0 | |
| 10 | RIVER BED Component Weightage 10 | ||||
| A- BED PROTECTION AND APRONS | |||||
| a) Large holes in the river bed? | Yes | Not So Bad | Some Qty | 2 | |
| b) Loss of material | Yes | Not So Bad | Some Qty | 2 | |
| c) Crates broken away from pier or abutment? | Yes | Not So Bad | Not Much Qty | 1 | |
| d) Damage to wires or ties? | NO Problem | -- | -- | 0 | |
| B- STONE PITCHING OR CONCRETE BED PROTECTION AND APRONS | |||||
| a) Scour at edge? | Yes | Bad | Not Much Qty | 4 | |
| b) Cracking? | Yes | Bad | Some Qty | 5 | |
| c) Spalling or stones missing? | NO Problem | -- | -- | 0 | |
| d) Erosion of surface? | Yes | Bad | Some Qty | 5 | |
| e) Corrosion of reinforcement? | Yes | Very Bad | Some Qty | 8 | |
End of Report