on Chainage 0.000 of road unknown
In District Rudraprayag Under CD Ukhimath Division
Critical Report on Bridge Condition
Form Filled By Rakesh Prakash [010087841]
Inspection Team
"Suspension bridge having span 102 m was built in 1983 .In 2013 kedarnath disater out 102 m 35 m towards left side portion is fully coverd with debries upto wind cables .The deck slab required replacement railing and suspender needs maintenance. Both abutments needa immidiate repair and maintannace both side anchor block are in bad condition.."
(Rakesh Prakash)
Executive Engineer Civil
on Jun 28, 2026
Detail Report
| # | Parameter | Problem ? | How Bad? | How Much? | |
|---|---|---|---|---|---|
| 1 | ROAD APPROCHES AND DECK Component Weightage 10 | ||||
| A- ROAD SURFACE NEAR BRIDGE | |||||
| a) Bumpy road surface near bridge? | Yes | Bad | Some Qty | 5 | |
| B- DRAINAGE | |||||
| a) Badly built road drainage near bridge? | Yes | Bad | Some Qty | 5 | |
| b) Blocked or damaged road drains? | NO Problem | -- | -- | 0 | |
| c) Water on the deck? | Yes | Not So Bad | Much Qty | 3 | |
| d) Blocked or damaged deck drains? | NO Problem | -- | -- | 0 | |
| C- WEARING COAT | |||||
| BITUMEN WEARING COURSE | |||||
| a) Surface breaking up or lifting off? | NO Problem | -- | -- | 0 | |
| b) Cracking above joints ? | NO Problem | -- | -- | 0 | |
| D- KERBS & FOOTPATHS | |||||
| a) Loose railing fixtures? | Yes | Bad | Much Qty | 6 | |
| a) Damaged or loose kerbs? | NO Problem | -- | -- | 0 | |
| 2 | PARAPETS, RAILINGS AND CRASH BARRIERS Component Weightage 10 | ||||
| a) Impact damaged? | Yes | Bad | Not Much Qty | 4 | |
| b) Loose or damaged fixings? | NO Problem | -- | -- | 0 | |
| c) Loose base of posts? | Yes | Bad | Some Qty | 5 | |
| d) Damaged coatirig or paint on steel surface? | NO Problem | -- | -- | 0 | |
| e) Corrosion on steel surface? | Yes | Bad | Not Much Qty | 4 | |
| f) Cracking on Masonary Parapets? | NO Problem | -- | -- | 0 | |
| g) Movement or bending of parapet? | Yes | Bad | Some Qty | 5 | |
| h) Poor pointing/ Plaster on parapet? | NO Problem | -- | -- | 0 | |
| i) Deterioration of bricks or stones? | NO Problem | -- | -- | 0 | |
| 3 | EXPANSION JOINT AT ABUTMENTS & PIERS Component Weightage 10 | ||||
| a) Damage to concrete of deck end or dirt wall near joint? | NO Problem | -- | -- | 0 | |
| b) Debris or vegetation in joint? | Yes | Bad | Not Much Qty | 4 | |
| c) Loose or damaged fixtures? | NO Problem | -- | -- | 0 | |
| d) Damage or corrosion to metal parts? | Yes | Bad | Some Qty | 5 | |
| e) Damage to rubber waterseals? | NO Problem | -- | -- | 0 | |
| 4 | RIVER Component Weightage 10 | ||||
| A- BLOCKAGES IN WATERWAY | |||||
| a) Debris against piers or abutments? | NO Problem | -- | -- | 0 | |
| b) Remains of old bridge under or upstream of the bridge? | NO Problem | -- | -- | 0 | |
| c) Fencing or buildings under bridge? | NO Problem | -- | -- | 0 | |
| d) Trees or bushes.growing under bridge? | Yes | Bad | Some Qty | 5 | |
| B- CHANGE IN RIVER COURSE | |||||
| a) River changing path upstream of bridge? | NO Problem | -- | -- | 0 | |
| b) New islands forming upstream of bridge? | NO Problem | -- | -- | 0 | |
| C- RIVER TRAINING WORKS | |||||
| a) River attack beyond the upstream end of river training works? | NO Problem | -- | -- | 0 | |
| b) Damage to walls? | NO Problem | -- | -- | 0 | |
| c) Loss of pitching? | NO Problem | -- | -- | 0 | |
| d) Damage to crates, timber, fencing, etc.? | NO Problem | -- | -- | 0 | |
| e) Damage to trees? | NO Problem | -- | -- | 0 | |
| 5 | SUPERSTRUCTURE Component Weightage 60 | ||||
| STEEL TRUSSES | |||||
| General | |||||
| a) Impact damage to girders, trusses or bracings? | NO Problem | -- | -- | 0 | |
| b) Debris or vegetation on beams, girders, trusses bracings or joints? | Yes | Bad | Not Much Qty | 4 | |
| c) Water coming through the deck? | Yes | Bad | Some Qty | 5 | |
| d) Water from the deck drainage flowing on to girders, trusses, beams or bracings? | NO Problem | -- | -- | 0 | |
| e) Not enough vertical & horizontal clearances? | Yes | Bad | Some Qty | 5 | |
| STEEL TRUSSES | |||||
| a) Deterioration of paint or galvanising? | Yes | Bad | Some Qty | 5 | |
| b) Corrosion? | NO Problem | -- | -- | 0 | |
| c) Bends in members? | NO Problem | -- | -- | 0 | |
| d) Bent or damaged joints? | NO Problem | -- | -- | 0 | |
| e) Bent or damaged bracing? | NO Problem | -- | -- | 0 | |
| f) Loose bolts or rivets? | NO Problem | -- | -- | 0 | |
| g) Cracking of steel members? | NO Problem | -- | -- | 0 | |
| STEEL UNDERSIDE OF DECK | |||||
| a) Deterioration of paint or galvanising? | NO Problem | -- | -- | 0 | |
| b) Corrosion? | Yes | Bad | Not Much Qty | 4 | |
| c) Bends in stringers or plates? | NO Problem | -- | -- | 0 | |
| d) Loose bolts or rivets? | NO Problem | -- | -- | 0 | |
| e) Cracking? | NO Problem | -- | -- | 0 | |
| 6 | BEARINGS Component Weightage 10 | ||||
| NOT APPLICABLE | |||||
| 7 | Right Side ABUTMENT, WING WALLS & RETAINING WALLS Component Weightage 10 | ||||
| A- GENERAL | |||||
| a) Erosion or scour at abutment? | NO Problem | -- | -- | 0 | |
| b) Damage to foundation? | NO Problem | -- | -- | 0 | |
| c) Movement of abutment? | NO Problem | -- | -- | 0 | |
| d) Debris against abutment? | NO Problem | -- | -- | 0 | |
| e) Vegetation growing on-or in abutment? | NO Problem | -- | -- | 0 | |
| f) Scour near to retaining walls? | NO Problem | -- | -- | 0 | |
| g) Movement of retaining walls? | NO Problem | -- | -- | 0 | |
| h) Water leaking down through the expansion joint? | NO Problem | -- | -- | 0 | |
| B- DRAINAGE SYSTEM | |||||
| a) Not enough weepholes? | Yes | Bad | Some Qty | 5 | |
| b) Weepholes not working? | NO Problem | -- | -- | 0 | |
| c) Water leaking through the abutment? | NO Problem | -- | -- | 0 | |
| C- CONCRETE WALLS | |||||
| a) Cracking? | NO Problem | -- | -- | 0 | |
| b) Spalling? | NO Problem | -- | -- | 0 | |
| c) Corrosion of reinforcement? | NO Problem | -- | -- | 0 | |
| d) Poor concrete? | NO Problem | -- | -- | 0 | |
| D- MASONRY WALLS | |||||
| a) Cracking? | NO Problem | -- | -- | 0 | |
| b) Bulging? | NO Problem | -- | -- | 0 | |
| c) Poor pointing? | NO Problem | -- | -- | 0 | |
| d) Deterioration of bricks or stones? | NO Problem | -- | -- | 0 | |
| E- EMBANKMENTS AND FILL IN FRONT OF ABUTMENT | |||||
| a) Scour at base of slopes? | NO Problem | -- | -- | 0 | |
| b) Slippage of fill? | NO Problem | -- | -- | 0 | |
| c) Erosion of fill? | NO Problem | -- | -- | 0 | |
| d) Cracking of road or embankment edge? | NO Problem | -- | -- | 0 | |
| e) Piping failure of fill? | NO Problem | -- | -- | 0 | |
| 8 | Left Side ABUTMENT, WING WALLS & RETAINING WALLS Component Weightage 10 | ||||
| A- GENERAL | |||||
| a) Erosion or scour at abutment? | NO Problem | -- | -- | 0 | |
| b) Damage to foundation? | NO Problem | -- | -- | 0 | |
| c) Movement of abutment? | NO Problem | -- | -- | 0 | |
| d) Debris against abutment? | NO Problem | -- | -- | 0 | |
| e) Vegetation growing on-or in abutment? | Yes | Bad | Not Much Qty | 4 | |
| f) Scour near to retaining walls? | NO Problem | -- | -- | 0 | |
| g) Movement of retaining walls? | NO Problem | -- | -- | 0 | |
| h) Water leaking down through the expansion joint? | NO Problem | -- | -- | 0 | |
| B- DRAINAGE SYSTEM | |||||
| a) Not enough weepholes? | Yes | Bad | Some Qty | 5 | |
| b) Weepholes not working? | NO Problem | -- | -- | 0 | |
| c) Water leaking through the abutment? | NO Problem | -- | -- | 0 | |
| C- CONCRETE WALLS | |||||
| a) Cracking? | NO Problem | -- | -- | 0 | |
| b) Spalling? | NO Problem | -- | -- | 0 | |
| c) Corrosion of reinforcement? | NO Problem | -- | -- | 0 | |
| d) Poor concrete? | NO Problem | -- | -- | 0 | |
| D- MASONRY WALLS | |||||
| a) Cracking? | NO Problem | -- | -- | 0 | |
| b) Bulging? | NO Problem | -- | -- | 0 | |
| c) Poor pointing? | NO Problem | -- | -- | 0 | |
| d) Deterioration of bricks or stones? | NO Problem | -- | -- | 0 | |
| E- EMBANKMENTS AND FILL IN FRONT OF ABUTMENT | |||||
| a) Scour at base of slopes? | NO Problem | -- | -- | 0 | |
| b) Slippage of fill? | NO Problem | -- | -- | 0 | |
| c) Erosion of fill? | NO Problem | -- | -- | 0 | |
| d) Cracking of road or embankment edge? | NO Problem | -- | -- | 0 | |
| e) Piping failure of fill? | NO Problem | -- | -- | 0 | |
| 9 | Embankments Component Weightage 10 | ||||
| A- STONE PITCHING SLOPE PROTECTION | |||||
| a) Cracking? | NO Problem | -- | -- | 0 | |
| b) Poor pointing? | NO Problem | -- | -- | 0 | |
| c) Scour or erosion at edge? | NO Problem | -- | -- | 0 | |
| d) Pieces broken off? | NO Problem | -- | -- | 0 | |
| e) Piping failure of fill? | NO Problem | -- | -- | 0 | |
| B- SLOPE PROTECTION WITH CRATES | |||||
| a) Not much movement of crates? | NO Problem | -- | -- | 0 | |
| b) Damage to crates or ties? | NO Problem | -- | -- | 0 | |
| C- PITCHING SLOPE PROTECTION WITH CONCRETE BLOCKS | |||||
| a) Slope getting washed out? | NO Problem | -- | -- | 0 | |
| b) Settlement? | NO Problem | -- | -- | 0 | |
| 10 | RIVER BED Component Weightage 10 | ||||
| A- BED PROTECTION AND APRONS | |||||
| a) Large holes in the river bed? | NO Problem | -- | -- | 0 | |
| b) Loss of material | NO Problem | -- | -- | 0 | |
| c) Crates broken away from pier or abutment? | NO Problem | -- | -- | 0 | |
| d) Damage to wires or ties? | NO Problem | -- | -- | 0 | |
| B- STONE PITCHING OR CONCRETE BED PROTECTION AND APRONS | |||||
| a) Scour at edge? | NO Problem | -- | -- | 0 | |
| b) Cracking? | NO Problem | -- | -- | 0 | |
| c) Spalling or stones missing? | NO Problem | -- | -- | 0 | |
| d) Erosion of surface? | NO Problem | -- | -- | 0 | |
| e) Corrosion of reinforcement? | NO Problem | -- | -- | 0 | |
End of Report