Bridge (ID- 1609 ) Inventory Report

Nivasini Bridge (Near Triveni Snagam)

Data finalized On 22 Apr 2023

By Er. Saiyad Tauqeer Alam

Last Rated On 11 Jun 2024

Rating 2.68%

Categorized As

XXXXX on XX-XX-XXXX

In District : Rudraprayag Under Division : CD Ukhimath

General

Bridge Type : Pedestrain Bridge
Structure No : 1
Feature Intersected : Madmaheshwar Ganga
Name of Bridge : Nivasini Bridge (Near Triveni Snagam)
Nearest Town : Ukhimath
Latitude (Northing) : 30.53694000
Longitude (Easting) : 79.09833000
Construction Year : 1983
Inventory Year : 2020

Geometric

Overall length (in meter) : 102.00
Total No of Span : 1
Maximuam Span (in meter) : 102.00
Span Arragment : 1x102m
No of Lane : 1.000
Overall Width (m) : 2.700
Carriageway Width (m) : 2.100
RS Footpath Width (m) : 0.000
LS Footpath Width (m) : 0.000
Approch Width i/c Shoulders (m) : 2.000
Gradient (%age) : 0
Skew Angle (degree) : 0.00
Radius of Curve in Plan (if Any) : 0.00

Design Data

HFL Highest Flood Level :
OFL Ordinary Flood Level : 1098.600
LWL Low Water Level : 1097.000
Design Velocity (m/Sec) :
Design Discharge (Cumecs) :
Soffit Level at Centre : 1105.000
Road Level at Centre : 1105.200
Design Scour Level at Pier :
Design Scour Level at Abutments :
Exposure Condition : Moderate
Seismic Importance factor : 0.0
Design Loading : NA
Load Rating : NA

Super-Structure

Superstructure Type : Suspension
Superstructure Material : Steel
Wearing Coat Type : Other
Expension Joint Type : Not Provided
Railing/Crash Barrier type : Steel rolled section
Bearing type : Not Provided

Sub-Structure

Founding Strata : Bouldery
Abutment Foundation Type : Open
Pier Foundation Type : NA
No of Piers : 0
Abutment Type : Stone Masonry
Pier Type : NA

Protection Work

Bank Protection Left Side of Up-stream : no protection work provided
Bank Protection Right Side of Up-stream : no protection work provided
Bank Protection Left Side of Down-stream : no protection work provided
Bank Protection Right Side of Down-stream : no protection work provided
Floor Protection on Up-stream : no protection work provided
Floor Protection on Down-stream : no protection work provided
Tratment for Corrosion Protection (if any) : no special treatment provided