Bridge (ID- 1449 ) Inventory Report

GIVAIN SROT On Chainage 26.215 of Starting from its junction with NH-58 near Meerut in the state of Uttar Pradesh and connecting Bijnor Najibabad Kotdwara Pauri and terminating at junction with NH -58 near Srinagar National Highway

Data finalized On 13 Jul 2023

By Arvind Joshi

Last Rated On 01 Jun 2024

Rating 1.23%

Categorized As

XXXXX on XX-XX-XXXX

In District : Pauri Under Division : NH Dhumakot

General

Bridge Type : Motor Bridge High Level
Structure No : 27/2
Feature Intersected : PANIYALI RIVER
Name of Bridge : GIVAIN SROT
Nearest Town : KOTDWARA
Latitude (Northing) : 29.75722200
Longitude (Easting) : 78.52671100
Construction Year : 2005
Inventory Year : 2021

Geometric

Overall length (in meter) : 50.00
Total No of Span : 2
Maximuam Span (in meter) : 25.00
Span Arragment : 2X25
No of Lane : 2.000
Overall Width (m) : 7.600
Carriageway Width (m) : 7.600
RS Footpath Width (m) : 1.650
LS Footpath Width (m) : 1.650
Approch Width i/c Shoulders (m) : 3.000
Gradient (%age) : 0
Skew Angle (degree) : 0.00
Radius of Curve in Plan (if Any) : 0.00

Design Data

HFL Highest Flood Level :
OFL Ordinary Flood Level :
LWL Low Water Level :
Design Velocity (m/Sec) :
Design Discharge (Cumecs) :
Soffit Level at Centre :
Road Level at Centre :
Design Scour Level at Pier :
Design Scour Level at Abutments :
Exposure Condition : Extreme
Seismic Importance factor : 1.0
Design Loading : Class AA
Load Rating : Class AA

Super-Structure

Superstructure Type : Solid slab
Superstructure Material : Reinforced concrete
Wearing Coat Type : Cement Concrete
Expension Joint Type : Single Strip/Box Seal Joint
Railing/Crash Barrier type : Cast-in-situ concrete
Bearing type : Roller & Rocker

Sub-Structure

Founding Strata : Bouldery
Abutment Foundation Type : Raft
Pier Foundation Type : Raft
No of Piers : 1
Abutment Type : RCC spill through type
Pier Type : RCC Solid

Protection Work

Bank Protection Left Side of Up-stream : M15 concrete blocks
Bank Protection Right Side of Up-stream : M15 concrete blocks
Bank Protection Left Side of Down-stream : M15 concrete blocks
Bank Protection Right Side of Down-stream : M15 concrete blocks
Floor Protection on Up-stream : no protection work provided
Floor Protection on Down-stream : no protection work provided
Tratment for Corrosion Protection (if any) : no special treatment provided