Bridge (ID- 636 ) Inventory Report

tadhag bridge On Chainage 106.490 of Bikhyasain Deghat Bungidhar Mehalchori Bachuwaban Chokhutiya state highway

Data finalized On 31 Oct 2022

By Er. Lalit Singh Sirari

Last Rated On 16 Jun 2024

Rating 0.00%

Categorized As

XXXXX on XX-XX-XXXX

In District : Almora Under Division : CD Ranikhet

General

Bridge Type : Road Over Bridge
Structure No : 106/1
Feature Intersected : tadhag (gadhera)
Name of Bridge : tadhag bridge
Nearest Town : amshari
Latitude (Northing) : 29.88553611
Longitude (Easting) : 79.38251389
Construction Year : 1990
Inventory Year : 2021

Geometric

Overall length (in meter) : 16.50
Total No of Span : 1
Maximuam Span (in meter) : 16.00
Span Arragment : 1x16.50
No of Lane : 1.000
Overall Width (m) : 5.200
Carriageway Width (m) : 4.400
RS Footpath Width (m) : 0.000
LS Footpath Width (m) : 0.000
Approch Width i/c Shoulders (m) : 4.800
Gradient (%age) : 0
Skew Angle (degree) : 0.00
Radius of Curve in Plan (if Any) : 0.00

Design Data

HFL Highest Flood Level : 953.200
OFL Ordinary Flood Level : 951.700
LWL Low Water Level : 951.500
Design Velocity (m/Sec) :
Design Discharge (Cumecs) :
Soffit Level at Centre :
Road Level at Centre :
Design Scour Level at Pier :
Design Scour Level at Abutments :
Exposure Condition : Moderate
Seismic Importance factor : 1.0
Design Loading : NA
Load Rating : NA

Super-Structure

Superstructure Type : T-beam and slab
Superstructure Material : Reinforced concrete
Wearing Coat Type : Cement Concrete
Expension Joint Type : Single Strip/Box Seal Joint
Railing/Crash Barrier type : Tubular steel
Bearing type : Roller & Rocker

Sub-Structure

Founding Strata : Hard clayey
Abutment Foundation Type : Raft
Pier Foundation Type : NA
No of Piers : 0
Abutment Type : Stone Masonry
Pier Type : NA

Protection Work

Bank Protection Left Side of Up-stream : wier creates 25 mtr
Bank Protection Right Side of Up-stream : 15.00 mtr wire creats
Bank Protection Left Side of Down-stream : no protection work provided
Bank Protection Right Side of Down-stream : no protection work provided
Floor Protection on Up-stream : no protection work provided
Floor Protection on Down-stream : no protection work provided
Tratment for Corrosion Protection (if any) : no special treatment provided